FIGURE 3-3: SIDE VIEW SANDBAG ENCLOSURE
e. Distance Criteria for Personnel Protective Shelters. Generally, personnel protective
shelters are not used at temporary OB/OD sites; however, if personnel protective shelters are
built, they will be located as far from the OD area as possible. All plans for proposed personnel
protective shelters will be designed IAW DOD 6055.9-STD and Army TM 5-1300, and reviewed
and approved by the OE MCX.
f. Distance Criteria for an Explosives Storage Area or Donor Explosives. The explosives
storage area or donor explosives will be located outside the PSD with a separation distance IAW
DOD 6055.9-STD. The actual distance to the explosives storage area will be determined by the
quantity of materials being held in the explosives storage area, the amount of material being
destroyed in the OD area during a single destruction event, and the type of munitions being
destroyed.
3-5